Evaluation of the diagnostic accuracy and cost of different methods for the assessment of severe anaemia in hospitalized children in Eastern Uganda

dc.contributor.authorOlupot-Olupot, Peter
dc.contributor.authorPrevatt, Natalie
dc.contributor.authorEngoru, Charles
dc.contributor.authorNteziyaremye, Nteziyaremye
dc.contributor.authorAmorut, Denis
dc.contributor.authorChebet, Martin
dc.contributor.authorSenyondo, Tonny
dc.contributor.authorOngodia, Paul
dc.contributor.authorNdila, Carolyne M.
dc.contributor.authorWilliams, Thomas N.
dc.contributor.authorMaitland, Kathryn
dc.date.accessioned2019-04-03T08:09:37Z
dc.date.available2019-04-03T08:09:37Z
dc.date.issued2018
dc.description.abstractBackground: Severe anaemia in children requiring hospital admission is a major public health problem in malaria-endemic Africa. Affordable methods for the assessment of haemoglobin have not been validated against gold standard measures for identifying those with severe anaemia requiring a blood transfusion, despite this resource being in short supply. Methods: We conducted a prospective descriptive study of hospitalized children aged 2 months – 12 years at Mbale and Soroti Regional Referral Hospitals, assessed to have pallor at triage by a nurse and two clinicians. Haemoglobin levels were measured using the HemoCue Hb 301 system (gold standard); the Haemoglobin Colour Scale; calorimetric and Sahli’s methods. We report clinical assessments of the degree of pallor, clinicians’ intention to transfuse, inter-observer agreement, limits of agreement using the Bland-Altman method, and the sensitivity and specificity of each method in comparison to HemoCue Results: We recruited 322 children assessed by the admitting nurse as having severe (164; 51.0%), moderate (99; 30.7%) or mild (57; 17.7%) pallor. Agreement between the clinicians and the nurse were good: Clinician A Kappa=0.68 (0.60–0.76) and Clinician B Kappa=0.62 (0.53–0.71) respectively ( P<0.0001 for both). The nurse, clinicians A and B indicated that of 94/116 (81.0%), 83/121 (68.6%) and 93/120 (77.5%) respectively required transfusion. HemoCue readings indicated anaemia as mild (Hb10.0–11.9g/dl) in 8/292 (2.7%), moderate (Hb5.0–9.9g/dl) in 132/292 (45.2%) and severe (Hb<5.0g/dl) in 152/292 (52.1%). Comparing to HemoCue® the Sahli’s method performed best in estimation of severe anaemia, with sensitivity 84.0% and specificity 87.9% and a Kappa score of 0.70 (0.64–0.80). Conclusions: Clinical assessment of severe pallor results has a low specificity for the diagnosis of severe anaemia. To target blood transfusion Hb measurement by either Hemocue® or Sahli’s method for the cost of USD 4 or and USD 0.25 per test, respectively would be more cost-effective.en_US
dc.description.sponsorshipWellcome Trust ; Core Support for the East African Major Overseas programme; Imperial College Centre for Global Researchen_US
dc.identifier.issn2398-502X
dc.identifier.urihttp://hdl.handle.net/20.500.12283/265
dc.language.isoenen_US
dc.publisherF1000Researchen_US
dc.subjectChilden_US
dc.subjectAfricaen_US
dc.subjectAnaemiaen_US
dc.subjectHaemoglobin measurementen_US
dc.subjectPrevalenceen_US
dc.subjectMalaria endemicen_US
dc.subjectInter-observer variationen_US
dc.subjectSensitivity and specificityen_US
dc.titleEvaluation of the diagnostic accuracy and cost of different methods for the assessment of severe anaemia in hospitalized children in Eastern Ugandaen_US
dc.typeArticleen_US

Olupot-Olupot_Eva_BUFHS_2018.pdf
1.44 MB
Adobe Portable Document Format
Journal Article

license.txt
1.71 KB
Item-specific license agreed upon to submission